The effect of membrane polarization on the time course of the end-plate current in frog sartorius muscle

1. Intracellular recordings of the end-plate current at different membrane potentials were made, using a voltage-clamp technique. 2. When the membrane potential is varied between about +40 and -120 mV, the half-decline time of the end-plate current increases from about 0·6 msec to about 1·6 msec....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of physiology 1969-10, Vol.204 (2), p.493-502
1. Verfasser: Kordas, M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:1. Intracellular recordings of the end-plate current at different membrane potentials were made, using a voltage-clamp technique. 2. When the membrane potential is varied between about +40 and -120 mV, the half-decline time of the end-plate current increases from about 0·6 msec to about 1·6 msec. 3. It is suggested that the stability of receptor—mediator complex is affected by the membrane potential.