The effect of membrane polarization on the time course of the end-plate current in frog sartorius muscle
1. Intracellular recordings of the end-plate current at different membrane potentials were made, using a voltage-clamp technique. 2. When the membrane potential is varied between about +40 and -120 mV, the half-decline time of the end-plate current increases from about 0·6 msec to about 1·6 msec....
Gespeichert in:
Veröffentlicht in: | The Journal of physiology 1969-10, Vol.204 (2), p.493-502 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | 1. Intracellular recordings of the end-plate current at different membrane potentials were made, using a voltage-clamp technique.
2. When the membrane potential is varied between about +40 and -120 mV, the half-decline time of the end-plate current increases
from about 0·6 msec to about 1·6 msec.
3. It is suggested that the stability of receptorâmediator complex is affected by the membrane potential. |
---|---|