SU‐C‐105‐07: A New Criterion for Detector Usability in Nonstandard Beam Dosimetry

Purpose: To accurately convert the detector signal to absorbed dose to water in nonstandard beams, beam quality correction factors (kQ) are required. To avoid calculating such factors, we define a criterion based on the hypothesis that, for a given detector, kQ is unity within a given tolerance. Thi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical Physics 2013-06, Vol.40 (6), p.84-84
Hauptverfasser: Kamio, Y, Bouchard, H
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose: To accurately convert the detector signal to absorbed dose to water in nonstandard beams, beam quality correction factors (kQ) are required. To avoid calculating such factors, we define a criterion based on the hypothesis that, for a given detector, kQ is unity within a given tolerance. This allows establishing detector‐specific critical regions to limit the field sizes usable experimentally without the need for evaluating kQ. Methods: A theoretical relation between the relative deviation of kQ from unity and a function that depends on dose response kernels is derived. Kernels are computed using the Monte Carlo user code egs_chamber for water and for three different ionization chambers (Exradin A12, A14 and A1SL), simulating 6 MV photon pencil beams at several lateral positions. Critical regions around the centroid of the chambers that guarantee kQ to remain within +/−0.005 from unity are obtained. For field sizes equal to the critical regions, kQ factors are calculated to validate the theoretical approach. Results: To limit kQ within +/−0.005 from unity, field sizes were determined to be 2.6× 5.2 cm2 for the A12, 3.8 × 3.8 cm2 for the A14 and 2.5 × 2.9 cm2 for the A1SL chamber. The corresponding kQ were found to be 1.0019 +/− 0.0026 for the A12, 1.0001 +/− 0.0047 for the A14 and 1.0011 +/− 0.0024 for the A1SL. These results are found within the expected deviation and fully support the validity of the new criterion. Conclusion: In this study, the limitation of the field size to a detector‐specific critical region allows small beam measurements to be done without the need for evaluating kQ factors. While this work will be extended to other types of detectors, the methodology will serve as a basis to study IMRT beams in the scope of new dosimetry protocols.
ISSN:0094-2405
2473-4209
DOI:10.1118/1.4813931