TU‐E‐BRB‐07: Optimal Treatment Beam Fluence Generation for Volumetric Arc Therapy Using Dose Image Backprojection with Initial Corona Calculation
Purpose: Derive a novel solution to the initial premise that IMRT fluence can be easily calculated using dose image backprojection. Method and Materials: Calculations were performed using MATLAB with the imaging toolbox using parallel beam geometry. A phantom matrix P was constructed with a concave...
Gespeichert in:
Veröffentlicht in: | Medical Physics 2010-06, Vol.37 (6), p.3400-3401 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose: Derive a novel solution to the initial premise that IMRT fluence can be easily calculated using dose image backprojection. Method and Materials: Calculations were performed using MATLAB with the imaging toolbox using parallel beam geometry. A phantom matrix P was constructed with a concave target, simultaneous integrated boost, and organ at risk with respective desired percent doses of 100, 110, and 40. Let R:SP be the backprojection of sinogram S of P. Iterative reconstruction using standard Ratio Method converges on a solution by computing Si+1 = Si * (P / R:SiP). For the novel Corona Method, we compute the corona using iterative backprojection reconstruction using ratios on only the target volumes T, T’ = R:S0T, and then superimpose the organ at risk, P’ = T’ + OAR. Iterative backprojection on P’ is then performed by successive addition correction, Si+1 = Si‐1 + (SO − Si), where SO is the sinogram of P’. Any negative intensities are set to zero during the iteration process. Target coverage is improved using the Compensated Phantom Method by computing a revised target based on the results Z of the process described thus far. We then define a new target T” = T’/Z and superimpose the OAR, such that P” = T” + OAR. The final procedure is to perform additive iteration constrained to contain only positive intensities. Results: Ratio Method: Target and boost areas receive their respective dose goals but the organ at risk unacceptable. Corona Method : OAR acceptable but poor target coverage. Compensated Phantom Method : Acceptable target coverage and the OAR goal is achieved. Conclusion: Dose image backprojection with initial corona calculation significantly reduces the dose to the organ at risk while maintaining acceptable target coverage. |
---|---|
ISSN: | 0094-2405 2473-4209 |
DOI: | 10.1118/1.3469290 |