Lead-acid storage battery recovery system using on–off constant current charge and short–large discharge pulses
We report a method of recovering degraded lead-acid batteries using an on–off constant current charge and short–large discharge pulse method. When the increases in inner impedance are within ∼20% of the initial impedance value, their system will permit discharge times to recover to a level approxima...
Gespeichert in:
Veröffentlicht in: | Electronics letters 2018-06, Vol.54 (12), p.777-779 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We report a method of recovering degraded lead-acid batteries using an on–off constant current charge and short–large discharge pulse method. When the increases in inner impedance are within ∼20% of the initial impedance value, their system will permit discharge times to recover to a level approximately matching their initial time values. In one experiment, when the discharge time of a |
---|---|
ISSN: | 0013-5194 1350-911X 1350-911X |
DOI: | 10.1049/el.2018.1079 |