Reduced Field‐of‐View Diffusion‐Weighted Magnetic Resonance Imaging of the Pancreas With Tilted Excitation Plane: A Preliminary Study
Background Reduced field‐of‐view diffusion‐weighted imaging (rDWI) with tilted two‐dimensional radiofrequency (RF) excitation planes has not yet been applied to the imaging of the pancreas although the utility of this technique which allows the acquisition of high‐quality images without aliasing art...
Gespeichert in:
Veröffentlicht in: | Journal of magnetic resonance imaging 2021-09, Vol.54 (3), p.715-720 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background
Reduced field‐of‐view diffusion‐weighted imaging (rDWI) with tilted two‐dimensional radiofrequency (RF) excitation planes has not yet been applied to the imaging of the pancreas although the utility of this technique which allows the acquisition of high‐quality images without aliasing artifacts in the phase‐encoding direction has been evaluated for brain and spinal cord imaging.
Purpose
To evaluate the visual image quality of the pancreas by tilting the excitation plane (tilted rDWI) in comparison to conventional DWI (cDWI) and rDWI without using the tilted excitation plane.
Study type
Retrospective.
Population
Thirty‐two patients evaluated for suspected pancreatobiliary diseases.
Field Strength/Sequence
Echo‐planar imaging DWI (cDWI, rDWI, and tilted rDWI) acquired at 3 T.
Assessment
Images from each DWI sequence were analyzed by five radiologists to compare image quality (conspicuity of pancreatic edges, interslice signal homogeneity, overall image quality, and conspicuity of focal pancreatic lesions) and artifacts (presence of blurring or ghosting artifacts, susceptibility artifacts, and aliasing artifact).
Statistical Tests
Shapiro–Wilk test was performed to assess whether data were normally distributed. Friedman test followed by Bonferroni‐adjusted Wilcoxon signed‐rank test for post hoc analysis was performed to compare image quality and artifact scores.
Results
The mean scores for conspicuity of pancreatic edges (3.36 vs. 2.37), interslice signal homogeneity (3.14 vs. 2.81), presence of ghosting artifacts (3.32 vs. 2.66), susceptibility artifacts (3.06 vs. 2.30), and aliasing artifacts (3.90 vs. 2.34), and overall image quality (3.49 vs. 2.36) were significantly higher in the tilted rDWI than in the rDWI (P |
---|---|
ISSN: | 1053-1807 1522-2586 |
DOI: | 10.1002/jmri.27590 |