A High-Fidelity Computationally Efficient Transient Model of Interior Permanent-Magnet Machine With Stator Turn Fault
An accurate transient model of interior permanent-magnet (IPM) machine with stator turn fault with due account of magnetic saturation is essential to develop robust and sensitive interturn fault detection algorithms and to evaluate drive controller performance and stability under fault conditions. T...
Gespeichert in:
Hauptverfasser: | , , |
---|---|
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | An accurate transient model of interior permanent-magnet (IPM) machine with stator turn fault with due account of magnetic saturation is essential to develop robust and sensitive interturn fault detection algorithms and to evaluate drive controller performance and stability under fault conditions. This paper proposes a general method of modeling stator turn fault using flux linkage map of IPM machine under fault extracted from finite-element (FE) analysis. Simulation results from the proposed fault model are compared against FE and experimental results. The results show that the proposed model matches well with experimental data. |
---|---|
DOI: | 10.1109/TIE.2015.2491884 |