Leakage Detection in Pipeline Based on Second Order Extended Kalman Filter Observer

In this paper, a new technique is proposed in order to detect, locate, as well as approximate the fluid leaks in a straight pipeline (without branching) by taking into consideration the pressure and flow evaluations at the ends of pipeline on the basis of data fusion from two methods: a steady-state...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Razvarz, S, Jafari, R, Alexander, G, Forooshani, M
Format: Artikel
Sprache:eng
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this paper, a new technique is proposed in order to detect, locate, as well as approximate the fluid leaks in a straight pipeline (without branching) by taking into consideration the pressure and flow evaluations at the ends of pipeline on the basis of data fusion from two methods: a steady-state approximation and Second-order Extended Kalman Filter (SEKF). The SEKF is on the basis of the second-order Taylor expansion of a nonlinear system unlike to the more popular First-order Extended Kalman Filter (FEKF). The suggested technique in this paper deals with just pressure head and flow rate evaluations at the ends of pipeline that has intrinsic sensor as well as process noise. A simulation example is given for demonstrating the validity of the proposed technique. It shows that the extended Kalman particle filter algorithm on the basis of the second-order Taylor expansion is effective and performs well in decreasing systematic deviations as well as running time.
DOI:10.1016/j.ifacol.2019.12.631