Effect of thermodilution injectate volume and temperature on the accuracy and precision of cardiac output measurements for healthy anesthetized horses

OBJECTIVE To compare the accuracy and precision of cardiac output (CO) measurements derived from 4 thermodilution protocols that used different injectate temperatures and volumes in healthy adult horses. ANIMALS 8 healthy adult horses. PROCEDURES Horses were anesthetized and instrumented with Swan-G...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of veterinary research 2021-10, Vol.82 (10), p.818-822
Hauptverfasser: Jenny, Jesse C. A., Hopster, Klaus, Hurcombe, Samuel D.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:OBJECTIVE To compare the accuracy and precision of cardiac output (CO) measurements derived from 4 thermodilution protocols that used different injectate temperatures and volumes in healthy adult horses. ANIMALS 8 healthy adult horses. PROCEDURES Horses were anesthetized and instrumented with Swan-Ganz catheters. The CO was derived from each of 4 thermodilution protocols (IV injection of physiologic saline [0.9% NaCl] solution chilled to < 5 degrees C at volumes of 1 mL/15 kg of body weight [protocol A; control], 1 mL/25 kg [protocol B], and 1 mL/35 kg [protocol C] or maintained at 17 degrees C at a volume of 1 mL/15 kg [protocol D]) 3 times during each of 5 measurement cycles, with a 30-minute interval between cycles. During each measurement cycle, protocol A was performed first, and protocols B, C, and D were performed in a randomized order. Mean CO and within-subject variance in CO were compared among the 4 protocols. RESULTS Mean CO did not differ significantly among the 4 protocols. The within-subject variance for CO measurements derived from protocols C and D, but not protocol B, was significantly greater than that for protocol A (control). CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that, in healthy adult horses, decreasing the thermodilution injectate volume to 1 mL/25 kg from the recommended volume of 1 mL/15 kg did not adversely affect the accuracy or precision of CO measurements. However, use of smaller injectate volumes or use of injectate at approximately room temperature is not recommended owing to a clinically unacceptable increase in CO measurement variability.
ISSN:0002-9645
1943-5681
DOI:10.2460/ajvr.82.10.818