The validity of using one force platform to quantify whole-body forces, velocities, and power during a plyometric push-up

Background Previous studies have typically measured velocity and power parameters during the push-up, either using one or two force platforms. The purpose of the study was to compare the force, velocity, and power parameters between the one-force-platform method and the two-force-platform method dur...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:BMC sports science, medicine & rehabilitation medicine & rehabilitation, 2021-08, Vol.13 (1), p.1-103, Article 103
Hauptverfasser: Sha, Zhanxin, Dai, Boyi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background Previous studies have typically measured velocity and power parameters during the push-up, either using one or two force platforms. The purpose of the study was to compare the force, velocity, and power parameters between the one-force-platform method and the two-force-platform method during plyometric push-ups. Methods Thirty-four physically active young adults participated in the study to perform the plyometric push-up. For the two-force-platform calculation method, the forces applied to the feet and hands were both measured. For the one-force-platform calculation method, the forces applied to the feet were assumed to be constant, while the forces applied to hands were measured by one force platform. Whole-body linear velocities were calculated based on the impulse and momentum theorem. Whole-body power was calculated as the product of the whole-body forces and velocities. Results The one-force-platform method overestimated the whole-body velocities and power compared with the two-force-platform method (1.39 +/- 0.37 m/s vs. 0.90 +/- 0.23 m/s, Cohen's d = 1.59, p < 0.05; 1.63 +/- 0.47 W/body weight vs. 1.03 +/- 0.29 W/body weight, Cohen's d = 1.49, p < 0.05). These differences were caused by the decreased forces applied to the feet compared to the initial value throughout most of the push-up phase. Large to perfect correlations (r = 0.55 - 0.99) were found for most variables between the two-force-platform and one-force-platform methods. Previous findings of push-up velocities and power using the two-force-platform and one-force-platform methods should be compared with caution. While the two-force-platform method is recommended, linear regression equations may be used to predict velocities and power parameters obtained from one force platform. Conclusions For those professionals who need to accurately quantify kinetic variables during the plyometric push-up, the two-force-platform method should be considered.
ISSN:2052-1847
2052-1847
DOI:10.1186/s13102-021-00330-z