Post-modification preparation of dual-emission Eu3+@Zn-II MOFs-based hybrid material and its application in highly sensitive ratiometric sensing for asthma wonder drug-procaterol enhanced by HCO3- and temperature
Currently, procaterol has been widely used as an asthma wonder drug; however, the overuse of procaterol easily leads to arrhythmia, and tachycardia decreased blood pressure. Metal organic frameworks (MOFs) are a new class of hybrid porous materials that have attracted great attention in the past 20...
Gespeichert in:
Veröffentlicht in: | Sensors and actuators. B, Chemical Chemical, 2021-10, Vol.344, Article 130199 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Currently, procaterol has been widely used as an asthma wonder drug; however, the overuse of procaterol easily leads to arrhythmia, and tachycardia decreased blood pressure. Metal organic frameworks (MOFs) are a new class of hybrid porous materials that have attracted great attention in the past 20 years. These metal-organic framework composites have highly efficient host-guest interactions and are excellent fluorescent sensing materials. In this work, an effective detection method to control the amount of procaterol was designed. A unique three-dimensional (3D) cluster-based metal-organic framework (MOF), namely [Zn2L(DEF)(3)](n) (Zn-MOF, H4L= [1,1 ':4 ',1 ''-terphenyl]- 3,3 '',5,5 ''-tetracarboxylic acid) can be prepared through the solvothermal method. Furthermore, through postsynthesis strategies, Eu3+ is loaded into cluster-based Zn-MOF to form dual-emission Eu3+@Zn-MOF, which can be employed as a ratiometric photoluminescent sensor for detecting the amount of wonder drug procaterol with a high K sensing constant value (6.12 x 10(5) [M-1]) and a low limit of detection (LOD) value (46.10 nM). In addition, HCO3- can be effectively detected with a low LOD value (8.28 nM) in procaterol solution while other anions do not respond, which also reveals the pharmacological effects between HCO3- and procaterol. Furthermore, in the HCO3- solution, Eu3+@Zn-MOF exhibits a more sensitive sensing performance for the procaterol with high sensitivity and excellent recovery. On the other hand, Eu3+@ Zn-MOF is a highly sensitive ratiometric temperature sensor in the range of 298-353 K. The detection sensitivity of Eu3+@Zn-MOF towards procaterol under the different physicochemical temperatures of the human body (303 K, 308 K, and 313 K) is also compared, This comparision indicates that temperature of 303 K has an enhanced sensing performance for procaterol in comparison with other detection temperatures. In conclusion, with the help of HCO3- and a suitable temperature (303 K), the detection sensitivity of Eu3+@Zn-MOF towards procaterol can be significantly improved and enhanced. |
---|---|
ISSN: | 0925-4005 |
DOI: | 10.1016/j.snb.2021.130199 |