Surface Acoustic Wave Biosensor with Laser-Deposited Gold Layer Having Controlled Porosity
Laser-deposited gold immobilization layers having different porosities were incorporated into love wave surface acoustic wave sensors (LW-SAWs). Variation of pulsed laser deposition parameters allows good control of the gold film morphology. Biosensors with various gold film porosities were tested u...
Gespeichert in:
Veröffentlicht in: | Chemosensors 2021-07, Vol.9 (7), p.173, Article 173 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Laser-deposited gold immobilization layers having different porosities were incorporated into love wave surface acoustic wave sensors (LW-SAWs). Variation of pulsed laser deposition parameters allows good control of the gold film morphology. Biosensors with various gold film porosities were tested using the biotin-avidin reaction. Control of the Au layer morphology is important since the biotin and avidin layer morphologies closely follow that of the gold. The response of the sensors to biotin/avidin, which is a good indicator of biosensor performance, is improved when the gold layer has increased porosity. Given the sizes of the proteins, the laser-deposited porous gold interfaces have optimal pore dimensions to ensure protein stability. |
---|---|
ISSN: | 2227-9040 2227-9040 |
DOI: | 10.3390/chemosensors9070173 |