Effect of optical fibre bending on plasma current measurement in ITER using a polarisation-OTDR setup

•Using a spun optical fibre and POTDR, plasma current in ITER can be measured.•The Jones formalism enables the modelling of spun sensing fibre and bending effect.•Maximum bending birefringence in the sensing fibre due to ITER geometry is ∼6.2 × 10−4 rad/m.•Sensing fibre bending has impact on ITER�...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Fusion engineering and design 2021-05, Vol.166, p.112279, Article 112279
Hauptverfasser: Dandu, Prasad, Gusarov, Andrei, Moreau, Philippe, Leysen, Willem, Bostyn, Charlotte, Mégret, Patrice, Wuilpart, Marc
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•Using a spun optical fibre and POTDR, plasma current in ITER can be measured.•The Jones formalism enables the modelling of spun sensing fibre and bending effect.•Maximum bending birefringence in the sensing fibre due to ITER geometry is ∼6.2 × 10−4 rad/m.•Sensing fibre bending has impact on ITER's low (0–1 MA) plasma current measurement. Accurate plasma current measurement is mandatory for the safe operation of the ITER. We investigate the possibility of performing this task using the polarisation-OTDR (optical time domain reflectometry). With this approach, an optical fibre placed on the outer surface of the vacuum vessel (VV) is used to measure the plasma current by analysing the Faraday effect induced SOP (state of polarisation) rotation of the backscattered light. The measurement accuracy depends on the extra linear birefringence resulting from the fibre bending related to the placement of the fibre on the vessel. In the present work, we assess this effect. Considering the difficulty in imitating such a bending geometry together with relevant currents in a lab environment, a simulation-based approach is developed to quantify the bending effect in the context of the ITER VV. The effect of fibre bending on the plasma current measurement accuracy in the expected ITER operating current range (0–17 MA) is analysed for different spun periods (SP) and beat lengths (LB) of the spun fibre placed around the VV. It is shown that a proper choice of LB and SP can alleviate the bending effect and achieve the ITER specifications regarding plasma current measurement accuracy.
ISSN:0920-3796
1873-7196
DOI:10.1016/j.fusengdes.2021.112279