Anti-Disturbance Finite-Time Adaptive Sliding Mode Backstepping Control for PV Inverter in Master-Slave-Organized Islanded Microgrid
With the aim to solve the problem related to the power chattering and anti-disturbance performance of a photovoltaic (PV) inverter in master-slave-organized islanded microgrid, an anti-disturbance finite-time adaptive sliding mode backstepping (DFA-SMB) controller is designed in this paper. First, t...
Gespeichert in:
Veröffentlicht in: | Energies (Basel) 2020-09, Vol.13 (17), p.4490, Article 4490 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | With the aim to solve the problem related to the power chattering and anti-disturbance performance of a photovoltaic (PV) inverter in master-slave-organized islanded microgrid, an anti-disturbance finite-time adaptive sliding mode backstepping (DFA-SMB) controller is designed in this paper. First, the topology and the second-order dynamic model of PV inverter are established based on constant DC voltage and constant reactive power control method. Subsequently, the backstepping method is adopted to perform the control of a high-order system. Moreover, a second-order sliding mode differentiator is used to realize the function of command-filter, solving the differential expansion problem caused by the derivation of virtual controller. Besides, the terminal sliding mode control (TSMC) is introduced into theq-axis controller andd-axis inner loop controller, increasing the robustness and reducing the convergence time of the system. Adaptive control and disturbance-observer (DO) are used to perform the adaptive estimation of model parameters and the observation of lumped disturbances, respectively, enhancing the dynamic characteristics of the controller. Finally, a master-slave-organized islanded microgrid with 100 kW PV array is established in MATLAB/Simulink. The results demonstrate that the proposed control method can effectively reduce power chattering and improve the anti-disturbance ability of the PV system. |
---|---|
ISSN: | 1996-1073 1996-1073 |
DOI: | 10.3390/en13174490 |