Long-term follow-up of the German post-market study for upper airway stimulation for obstructive sleep apnea

Purpose Upper airway stimulation (UAS) is an effective treatment for obstructive sleep apnea (OSA) in positive airway pressure (PAP) failure. Most reports have presented short-term data, so long-term safety and efficacy reports are rare. The German post-market study (G-PMS) has followed approximatel...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Sleep & breathing 2020-09, Vol.24 (3), p.979-984
Hauptverfasser: Steffen, Armin, Sommer, Ulrich J., Maurer, Joachim T., Abrams, Nils, Hofauer, Benedikt, Heiser, Clemens
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose Upper airway stimulation (UAS) is an effective treatment for obstructive sleep apnea (OSA) in positive airway pressure (PAP) failure. Most reports have presented short-term data, so long-term safety and efficacy reports are rare. The German post-market study (G-PMS) has followed approximately 60 patients from three implanting centers for several years. Methods Patients with OSA and PAP failure qualified for the G-PMS by the absence of obesity class 2 an AHI between 15 and 65 events/h and absence of complete concentric collapse at the velum during drug-induced sleep endoscopy. Optional 2- and 3-year follow-ups after implantation were collected during routine clinical practice. We measured respiratory parameters such as apnea–hypopnea index (AHI) and oxygen desaturation index (ODI) and daytime sleepiness using the Epworth sleepiness scale (ESS) in a per protocol analysis. Usage was calculated from device-downloaded reports. Device-related complications were documented. Results Of the 60 original patients, 41 returned for 2-year follow-up, and 38 for 3 years. About 76% at 2 years and 68% at 3 years met the criterion of therapy success defined as an AHI below 15/h. The median AHI was reduced from 28.6/h (baseline) to 9.0/h (2 years) and 10.0/h (3 years); whereas median ODI decreased from 27.0 to 6.3/h (2 years), and 8.3/h (3 years). Median ESS improved from baseline 13 points to 4 (2 years) and 6 (3 years). Usage was stable at approximately 45 h per week at 2 and 3 years. Serious device-related adverse events were rare, with two-device explantation between 12 to 36 months postoperatively. Conclusions The German multi-center long-term outcomes compare favorably with previously published studies. Respiratory and sleepiness efficacy outcomes were sustained over 2 and 3 years, with a favorable safety profile, supporting the safety and efficacy of a chronic implantable therapy.
ISSN:1520-9512
1522-1709
DOI:10.1007/s11325-019-01933-0