Fault Detection Method Using a Convolution Neural Network for Hybrid Active Neutral-Point Clamped Inverters

This article presents an open-switch fault detection method for a hybrid active neutral-point clamped (HANPC) inverter based on deep learning technology. The HANPC inverter generates a three-level output voltage with four silicon switches and two silicon carbide switches per phase. The probability o...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE access 2020, Vol.8, p.140632-140642
Hauptverfasser: Kim, Sang-Hun, Yoo, Dong-Yeon, An, Sang-Won, Park, Ye-Seul, Lee, Jung-Won, Lee, Kyo-Beum
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This article presents an open-switch fault detection method for a hybrid active neutral-point clamped (HANPC) inverter based on deep learning technology. The HANPC inverter generates a three-level output voltage with four silicon switches and two silicon carbide switches per phase. The probability of open fault in switching devices increases because of the large number of switches of the entire power converter. The open-switch fault causes distortion of output currents. A convolution neural network (CNN) comprising several convolution layers and fully connected layers is used to extract features of distorted currents. A CNN network was trained using three-phase current information to determine the location of the open-switch fault. Our proposed CNN model can accurately detect approximately 99.6% of open-switch faults without requiring additional circuitry and regardless of the current level within an average time of 1.027ms. The feasibility and effectiveness of the proposed method are verified by experimental results.
ISSN:2169-3536
2169-3536