Stanazolol derived ELISA as a sensitive forensic tool for the detection of multiple 17α-methylated anabolics
[Display omitted] •Stanazolol antigens and polyclonal rabbit antibodies (RAbs) were produced.•Biotinylated antigens were synthesized.•Two highly stable ELISA methods were developed.•Sensitivity towards multiple 17α-methylated anabolics was identified.•Developed methods were applied for real samples...
Gespeichert in:
Veröffentlicht in: | Steroids 2020-03, Vol.155, p.108550-108550, Article 108550 |
---|---|
Hauptverfasser: | , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | [Display omitted]
•Stanazolol antigens and polyclonal rabbit antibodies (RAbs) were produced.•Biotinylated antigens were synthesized.•Two highly stable ELISA methods were developed.•Sensitivity towards multiple 17α-methylated anabolics was identified.•Developed methods were applied for real samples analyses.
Two valuable forensic tools based on enzyme-linked immunoassays (ELISAs) for the analysis of 17α-methylated steroids were developed using haptens of stanazolol and its conjugates with biotin. Haptens containing terminal carboxylic group were conjugated to bovine serum albumin (BSA), rabbit serum albumin (RSA) or ovalbumin (OVA). Eight batches of antisera (RAbs) obtained by immunization of rabbits were tested in an indirect competitive ELISA system using immobilization of RSA conjugate (RSA/hapten) and competitor immobilization of the biotinylated conjugate (AB-ELISA) to avidin (avidin/hapten). The best results were achieved with the RAb 212 antibodies in RSA/ST-3 and avidin/ST-10 assembled variants. For the RSA/ST-3 system, an IC50 of 0.3 ng/mL and a detection limit of 0.02 ng/mL were measured. In case of avidin/ST-10 variant, IC50 was of 3.9 ng/mL and a detection limit of 0.57 ng/mL were obtained. The effect of solvent was tested as well as the stability of coated microtiter plates over four-month period. The cross-reactivity of the developed assays with other anabolic steroids was tested and high sensitivity towards 17α-methylated steroids was observed. RSA/ST-3 assay showed significant cross-reactivity with 17α-methyltestosterone (81.2%), oxymetholone (30.4%), methandienone (10.0%) and methyl dihydrotestosterone (7.7%). Similarly, in the avidin/ST-10 assay, 17α-methyltestosterone (34.5%), mestanolone (32.1%), oxymetholone (22.7%), methandienone (14.2%), 9-dehydromethyltestosterone (12.5%) and oxandrolone (1.2%) exhibited high cross-reactivity. The functionality of the developed systems was verified by the successful identification of a series of 17α-methylated anabolic steroids in a set of real samples including pharmaceutical preparations seized by the Police of the Czech Republic on the black market. |
---|---|
ISSN: | 0039-128X 1878-5867 |
DOI: | 10.1016/j.steroids.2019.108550 |