Introduction: Endobronchial ultrasound (EBUS) is an endoscopic diagnostic procedure combining flexible fibrobronchoscopy with ultrasound techniques; it allows transbronchial needle aspiration biopsy for the diagnosis and staging of mediastinal masses. We present our preliminary experience with the u...
Gespeichert in:
Veröffentlicht in: | Tumori 2021-02, Vol.107 (1), p.86-90, Article 0300891619871104 |
---|---|
Hauptverfasser: | , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Introduction:
Endobronchial ultrasound (EBUS) is an endoscopic diagnostic procedure combining flexible fibrobronchoscopy with ultrasound techniques; it allows transbronchial needle aspiration biopsy for the diagnosis and staging of mediastinal masses. We present our preliminary experience with the use of the i-gel O2 supraglottic airway device for management of EBUS procedures.
Methods:
An observational study on 39 patients who underwent EBUS under general anesthesia was performed. Airways were managed with i-gel O2 by anesthesiologists unfamiliar with it. Data collected included patient characteristics, i-gel O2 positioning, mechanical ventilation, procedure, and complications occurring during and after the EBUS.
Results:
The i-gel airway was successfully positioned during the first attempt in 34/39 cases (87.2%). No failed positioning was recorded. The EBUS scope easily passed through the i-gel in all patients and in 14 (35.6%) cases it was also inserted through the esophagus allowing the examination or fine needle aspiration of paraesophageal lymph nodes. In one case, during the EBUS procedure, the i-gel was dislocated but easily put in place again. During EBUS, air leakages were significant in 2 cases (5.1%) and minimal in 14 cases (35.9%). A brief self-solved laryngospasm and a bronchospasm during bronchoscopy were recorded. After recovery, no patients had dysphagia; mild odynophagia and pharyngodinia were referred by 2 (5.1%) and 12 (30.1%) patients, respectively.
Conclusions:
The i-gel O2 airway is easy to position and manage even for anesthesiologists unfamiliar with it. This supraglottic airway device is suitable for a complete endosonographic evaluation of the mediastinum. |
---|---|