Thermal-hydraulic modeling and analysis of spool valve with sloping U-shape notch by bond graph

To increase the efficiency and reliability of the thermodynamics analysis of the spool valve, the precise function expression of the flow area for the sloping U-shape notch orifice versus the spool stroke and thermal-hydraulic bond graph based on the conservation of mass and energy were introduced....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Central South University 2015-11, Vol.22 (11), p.4205-4212
1. Verfasser: 娄磊 吴万荣 王兆强 梁向京
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:To increase the efficiency and reliability of the thermodynamics analysis of the spool valve, the precise function expression of the flow area for the sloping U-shape notch orifice versus the spool stroke and thermal-hydraulic bond graph based on the conservation of mass and energy were introduced. Subsequently, the connection rule for the bond graph elements and the method to construct the complete thermal-hydraulic system model were proposed. On the basis of heat transfer analysis of a typical hydraulic circuit containing the spool valve, the lumped parameter for mathematical model of the system was given. At last, the reliability of the mathematical model of the flow area and the thermal-hydraulic system for the sloping U-shape notch orifice on the spool were demonstrated by the test. The good agreement between the simulation results and experimental data demonstrates the validity of the modeling method.
ISSN:2095-2899
2227-5223
DOI:10.1007/s11771-015-2968-x