Establishment of water quality index (Na +, Ca 2+) for purified water reused to zinc electrolysis process

The effects of Na + and Ca 2+ in the purified water on the conductivity of zinc electrolyte and the current efficiency of zinc electrolysis were studied by the alternating current bridge method and the simulated electrolysis experiments, and the water quality index of reused water was established. T...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Transactions of Nonferrous Metals Society of China 2009-04, Vol.19 (2), p.484-488
Hauptverfasser: CHAI, Li-yuan, XIAO, Hai-juan, WANG, Yun-yan, PEI, Fei, SHU, Yu-de, ZHANG, Jin-long
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The effects of Na + and Ca 2+ in the purified water on the conductivity of zinc electrolyte and the current efficiency of zinc electrolysis were studied by the alternating current bridge method and the simulated electrolysis experiments, and the water quality index of reused water was established. The results show that the conductivity of the solution and the current efficiency decrease as these two kinds of positive ions are added in the electrolyte. The effect of Ca 2+ is much more remarkable than that of Na +. ρ(Na +)≤ 8 g/L and ρ(Ca 2+)≤20 mg/L are the quality indexes in the zinc electrolysis process and the concentrations of Na + and Ca 2+ in the purified water reused to the process should be less than the limited values, i.e. the water quality index of the purified water should be controlled by its reused amount.
ISSN:1003-6326
DOI:10.1016/S1003-6326(08)60300-3