Cold Model Study and Commercial Test on Novel Vapor-Liquid Distributor of Hydroprocessing Reactor
TE6; A novel vapor-liquid distributor was developed on the basis of sufficient study on the existing distributors applied in hydroprocessing reactors.The cold model test data showed that the fluid distribution performance of the novel vapor-liquid distributor was evidently better than the traditiona...
Gespeichert in:
Veröffentlicht in: | 中国炼油与石油化工(英文版) 2007-06 (2), p.49-54 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | TE6; A novel vapor-liquid distributor was developed on the basis of sufficient study on the existing distributors applied in hydroprocessing reactors.The cold model test data showed that the fluid distribution performance of the novel vapor-liquid distributor was evidently better than the traditional one.Commercial tests of the new distributor were carried out in the 300 kt/a gas oil hydrotreating reactor at SINOPEC Changling Branch Company,showing that the new vapor-liquid distributor could improve the fluid distribution,promote the hydrotreating efficiency and lead to better performance than the traditional one. |
---|---|
ISSN: | 1008-6234 |