Cooling Water Flow Rate Calculation for Hearth of Large Blast Furnaces
The cooling water flow rate for hearth of large blast furnaces was calculated by simulation. The results show that the cooling water flow rate shall be above 4 200m3/ h for hearth of large blast furnaces; to meet requirements of the increasing smelting intensity and to ensure the safety at the end o...
Gespeichert in:
Veröffentlicht in: | China's refractories 2015-04, Vol.24 (2), p.16-20 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The cooling water flow rate for hearth of large blast furnaces was calculated by simulation. The results show that the cooling water flow rate shall be above 4 200m3/ h for hearth of large blast furnaces; to meet requirements of the increasing smelting intensity and to ensure the safety at the end of the first campaign,the designed maximum cooling water flow rate should be 5 900m3/ h; according to the flow distribution stability and the calculated resistance loss,hearth cooling stave pipes with the specification of 76 mm × 6 mm shall be adopted to assure the flow velocity in pipes of hearth cooling stave in the range of 1. 9- 2. 3 m / s. |
---|---|
ISSN: | 1004-4493 |