Research of stress corrosion cracking of T225NG titanium alloy in loop water of high temperature and high pressure
Double cantilever beam (DCB) specimens were used to research the stress corrosion cracking of T225NG titanium alloy in loop water of high temperature and high pressure. DCB specimens were forced pre-stress, put into high pressure ataoclave , and the stress corrosion and crack expansion of specimens...
Gespeichert in:
Veröffentlicht in: | China welding 2006-03, Vol.15 (1), p.26-29 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Double cantilever beam (DCB) specimens were used to research the stress corrosion cracking of T225NG titanium alloy in loop water of high temperature and high pressure. DCB specimens were forced pre-stress, put into high pressure ataoclave , and the stress corrosion and crack expansion of specimens were observed and measured in 500 h, 1 000 h and 2000 h respectively. The results show that small expansion occurred along the direction of pre-cracking. According to calculation, the speed of cracking expansion is lower than 10 -9 m/s in 500 h and the value of K ISCC /KI is higher than 0. 75, which proves that T225NG has an excellent corrosion resistance in loop water. The main reason is that there is an oxide film on the surface of specimens. According to the analysis of energy dispersive spectroscopy (EDS) and X-ray diffraction ( XRD ) , the oxide film consists of TiO2. Therefore, the oxide film at the crack tip impedes the hydrogen separating out from the cathode to penetrate into titanium alloy and resists hydrogen embrittlement. |
---|---|
ISSN: | 1004-5341 |