Reliability investigation of demolition initiation network for urban viaduct
This paper presented the delay characteristics of relay point detonator used in multiple parallel initia- tion networks and proposed the simple formula to calculate expectations of relay point initiation time. Corre- sponding reliability standards were established based on the different scale of non...
Gespeichert in:
Veröffentlicht in: | 中国工程科学:英文版 2014, Vol.12 (6), p.80-84 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This paper presented the delay characteristics of relay point detonator used in multiple parallel initia- tion networks and proposed the simple formula to calculate expectations of relay point initiation time. Corre- sponding reliability standards were established based on the different scale of non-electric initiation network. A multiple parallel initiation network were created, which could not only avoid the occurrence of the viaduct roll- over during dumping process, but also improve the reliability standard and realize the unlimited segmentation. Results could provide a good reference for the design of viaduct blasting initiation network. |
---|---|