Enzyme-linked immunosorbent assays for quantification of MMMAE-conjugated ADCs and total antibodies in cynomolgus monkey sera

Antibody-drug conjugates(ADCs)are commonly heterogeneous and require extensive assessment of exposure-efficacy and exposure-safety relationships in preclinical and clinical studies.In this study,we report the generation of a monoclonal antibody against monomethyl auristatin E(MMAE)and the developmen...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:药物分析学报(英文版) 2022, Vol.12 (4), p.645-652
Hauptverfasser: Min Pei, Tingting Liu, Lu Ouyang, Jianhua Sun, Xiaojie Deng, Xiaomin Sun, Wei Wu, Peng Huang, Yi-Li Chen, Xiaorong Tan, Xiaoyue Liu, Peng Zhu, Yongzhen Liu, Deheng Wang, Junliang Wu, Qi Wang, Guifeng Wang, Likun Gong, Qiuping Qin, Chunhe Wang
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Antibody-drug conjugates(ADCs)are commonly heterogeneous and require extensive assessment of exposure-efficacy and exposure-safety relationships in preclinical and clinical studies.In this study,we report the generation of a monoclonal antibody against monomethyl auristatin E(MMAE)and the development,validation,and application of sensitive and high-throughput enzyme-linked immunosor-bent assays(ELISA)to measure the concentrations of MMAE-conjugated ADCs and total antibodies(tAb,antibodies in ADC plus unconjugated antibodies)in cynomolgus monkey sera.These assays were suc-cessfully applied to in vitro plasma stability and pharmacokinetic(PK)studies of SMADC001,an MMAE-conjugated ADC against trophoblast cell surface antigen 2(TROP-2).The plasma stability of SMADC001 was better than that of similar ADCs coupled with PEG4-Val-Cit,Lys(m-dPEG24)-Cit,and Val-Cit linkers.The developed ELISA methods for the calibration standards of ADC and tAb revealed a correlation be-tween serum concentrations and the OD450 values,with R2 at 1.000,and the dynamic range was 0.3-35.0 ng/mL and 0.2-22.0 ng/mL,respectively;the intra-and inter-assay accuracy bias%ranged from-12.2%to-5.2%,precision ranged from-12.4%to-1.4%,and the relative standard deviation(RSD)was less than 6.6%and 8.7%,respectively.The total error was less than 20.4%.The development and validation steps of these two assays met the acceptance criteria for all addressed validation parameters,which suggested that these can be applied to quantify MMAE-conjugated ADCs,as well as in PK studies.Furthermore,these assays can be easily adopted for development of other similar immunoassays.
ISSN:2095-1779