Electrochemical behavior of Cu-Zn-Al shape memory alloy after surface modification by electroless plated Ni-P
The electrochemical behavior of Cu-Zn-Al shape memory alloy (SMA) with and without electroless plated Ni-P was investigated by electrochemical methods in artificial Tyrode's solution. The results showed that Cu-Zn-Al SMA engendered dezincification corrosion in Tyrode's solution. The anodic...
Gespeichert in:
Veröffentlicht in: | Rare metals 2004-12, Vol.23 (4), p.317-321 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The electrochemical behavior of Cu-Zn-Al shape memory alloy (SMA) with and without electroless plated Ni-P was investigated by electrochemical methods in artificial Tyrode's solution. The results showed that Cu-Zn-Al SMA engendered dezincification corrosion in Tyrode's solution. The anodic active current densities as well as electrochemical dissolution sensitivity of the electroless plated Ni-P Cu-Zn-Al SMA increased with NaCl concentration rising, pH of solution decreasing and environmental temperature uprising. X-ray diffraction analysis indicated that after surface modification by electroless plated Ni-P, an amorphous plated film formed on the surface of Cu-Zn-Al SMA. This film can effectively isolate matrix metal from corrosion media and significantly improve the electrochemical property of Cu-Zn-Al SMA in artificial Tyrode's solution. (Copper alloys considered as candidate biomedical material to replace TiNi shape memory alloys.) |
---|---|
ISSN: | 1001-0521 |