Simulation study of slow extraction for the Shanghai Advanced Proton Therapy facility
The Shanghai Advanced Proton Therapy facility employs third-integer slow extraction. In order to achieve accurate treatment, high-quality spill is needed. Therefore, parameters that may affect slow extraction should be investigated by simulation. A computer model of the syn- chrotron operation slow...
Gespeichert in:
Veröffentlicht in: | Nuclear science and techniques 2017-09, Vol.28 (9), p.1-7, Article 120 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The Shanghai Advanced Proton Therapy facility employs third-integer slow extraction. In order to achieve accurate treatment, high-quality spill is needed. Therefore, parameters that may affect slow extraction should be investigated by simulation. A computer model of the syn- chrotron operation slow extraction was constructed with MATLAB~. By simulating the motion of the circulating protons, we could quantify the influence of machine and initial beam parameters on properties of the extracted beam, such as ripple, uniformity, stability, on- and off-time of the spill and spill width in the synchrotron. Suitable design parameters including the horizontal tunes, power supply ripple, longitudinal RF cavity voltage, RF- KO and the chromaticities were determined. |
---|---|
ISSN: | 1001-8042 2210-3147 |
DOI: | 10.1007/s41365-017-0273-0 |