Primary study on holdup measurement of ^235U in pipe using γ-ray spectrometry and Monte Carlo simulation

The pipe holdup measurement is very important for decommissioning nuclear facilities and nuclear-material control and accounting. The absolute detection efficiencies (εsp) of full-energy γ rays peak under different source density distribution function have been simulated using the Monte Carlo (MC) s...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nuclear science and techniques 2006-08, Vol.17 (4), p.241-244
Hauptverfasser: WU, Lun-Qiang, WEI, Meng-Fu, ZHANG, Lian-Ping, YANG, Suo-Long
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The pipe holdup measurement is very important for decommissioning nuclear facilities and nuclear-material control and accounting. The absolute detection efficiencies (εsp) of full-energy γ rays peak under different source density distribution function have been simulated using the Monte Carlo (MC) software, and the counting rates (no) of the characteristic γ rays have been measured using the γ spectrometer followed by the calculation of the holdup. The holdup is affected by the energy of γ rays, distance at which they are detected, pipe material, thickness, and source distribution of pipe, especially source distribution at a short distance. The comparative test of ^235U reference materials on the inner wall of Fe and A1 pipes (the total mass of ^235U is 44.6 mg and 222.8 mg, respectively) have been accomplished using this method. The determined result of ^235U is 43.2mg (U0.95rel=5.4%) and 216.2mg (U0.95rel= 3.2%), respectively, which are in accordance with the reference values.
ISSN:1001-8042
2210-3147
DOI:10.1016/S1001-8042(06)60045-6