Seismic behavior of concrete filled steel tubular arch structures
Shaking table tests of a 1:10 scale arch model performed to investigate the seismic behavior and resistance ofconcrete filled steel tubular (CFT) arch structures are described in this paper. The El-Centro record and Shanghai artificial wave were adopted as the input excitation. The entire test proce...
Gespeichert in:
Veröffentlicht in: | Earthquake Engineering and Engineering Vibration 2005-06, Vol.4 (1), p.107-115 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Shaking table tests of a 1:10 scale arch model performed to investigate the seismic behavior and resistance ofconcrete filled steel tubular (CFT) arch structures are described in this paper. The El-Centro record and Shanghai artificial wave were adopted as the input excitation. The entire test process can be divided into three stages depending on the lateral brace configurations, i.e., fully (five) braced, two braces removed, and all braces removed. A total of 46 tests, starting from the elastic state to failure condition, have been conducted. The natural vibration frequencies, responses of acceleration, displacement and strain were measured. From the test results, it is demonstrated that the CFT arch structures are capable of resisting severe ground motions and that CFT arches offer a credible alternative to reinforced concrete arches, especially in regions of high seismic intensity. |
---|---|
ISSN: | 1671-3664 1993-503X |
DOI: | 10.1007/s11803-005-0029-4 |