Feedback Control System for Antenna Phase Difference in the LHCD Experiments

TL61; It is well accepted that lower hybrid current drive (LHCD) is the most efficient method for non-inductive current drive in fusion devices and the effect of the current drive is dependent on not only microwave power but also its grill phase shift. This paper presents a new kind of feedback cont...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Plasma science & technology 2005-12, Vol.7 (6), p.3107-3110, Article 3107
Hauptverfasser: Min, Jiang, Guangli, Kuang, Jiafang, Shan, Lin, Jian'an, Jun, Kong, Team, HT-7
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:TL61; It is well accepted that lower hybrid current drive (LHCD) is the most efficient method for non-inductive current drive in fusion devices and the effect of the current drive is dependent on not only microwave power but also its grill phase shift. This paper presents a new kind of feedback control system for antenna phase difference in LHCD experiments. In this high-speed control system, a lot of new technologies and methods are incorporated. The results of the experiments show a very good agreement with the system design.
ISSN:1009-0630
DOI:10.1088/1009-0630/7/6/007