Feedback Control System for Antenna Phase Difference in the LHCD Experiments
TL61; It is well accepted that lower hybrid current drive (LHCD) is the most efficient method for non-inductive current drive in fusion devices and the effect of the current drive is dependent on not only microwave power but also its grill phase shift. This paper presents a new kind of feedback cont...
Gespeichert in:
Veröffentlicht in: | Plasma science & technology 2005-12, Vol.7 (6), p.3107-3110, Article 3107 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | TL61; It is well accepted that lower hybrid current drive (LHCD) is the most efficient method for non-inductive current drive in fusion devices and the effect of the current drive is dependent on not only microwave power but also its grill phase shift. This paper presents a new kind of feedback control system for antenna phase difference in LHCD experiments. In this high-speed control system, a lot of new technologies and methods are incorporated. The results of the experiments show a very good agreement with the system design. |
---|---|