External and Internal Validation of a Computer Assisted Diagnostic Model for Detecting Multi-Organ Mass Lesions in CT images

Objective We developed a universal lesion detector (ULDor) which showed good performance in in-lab experiments. The study aims to evaluate the performance and its ability to generalize in clinical setting via both external and internal validation. Methods The ULDor system consists of a convolutional...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chinese medical sciences journal 2021-09, Vol.36 (3), p.210-217
Hauptverfasser: Xu, Lian-Yan, Yan, Ke, Lu, Le, Zhang, Wei-Hong, Chen, Xu, Huo, Xiao-Fei, Lu, Jing-Jing
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objective We developed a universal lesion detector (ULDor) which showed good performance in in-lab experiments. The study aims to evaluate the performance and its ability to generalize in clinical setting via both external and internal validation. Methods The ULDor system consists of a convolutional neural network (CNN) trained on around 80K lesion annotations from about 12K CT studies in the DeepLesion dataset and 5 other public organ-specific datasets. During the validation process, the test sets include two parts: the external validation dataset which was comprised of 164 sets of non-contrasted chest and upper abdomen CT scans from a comprehensive hospital, and the internal validation dataset which was comprised of 187 sets of low-dose helical CT scans from the National Lung Screening Trial (NLST). We ran the model on the two test sets to output lesion detection. Three board-certified radiologists read the CT scans and verified the detection results of ULDor. We used positive predictive value (PPV) and sensitivity to evaluate the performance of the model in detecting space-occupying lesions at all extra-pulmonary organs visualized on CT images, including liver, kidney, pancreas, adrenal, spleen, esophagus, thyroid, lymph nodes, body wall, thoracic spine, . Results In the external validation, the lesion-level PPV and sensitivity of the model were 57.9% and 67.0%, respectively. On average, the model detected 2.1 findings per set, and among them, 0.9 were false positives. ULDor worked well for detecting liver lesions, with a PPV of 78.9% and a sensitivity of 92.7%, followed by kidney, with a PPV of 70.0% and a sensitivity of 58.3%. In internal validation with NLST test set, ULDor obtained a PPV of 75.3% and a sensitivity of 52.0% despite the relatively high noise level of soft tissue on images. Conclusions The performance tests of ULDor with the external real-world data have shown its high effectiveness in multiple-purposed detection for lesions in certain organs. With further optimisation and iterative upgrades, ULDor may be well suited for extensive application to external data.
ISSN:1001-9294
DOI:10.24920/003968