Light distribution in leaf chambers and its consequences for photosynthesis measurements

The impact of a heterogeneous distribution of actinic light within a leaf chamber for photosynthetic measurements by gas exchange on the photosynthesis-irradiance relationship was investigated. High-resolution light distributions were measured over the area of a commercially available clamp-on leaf...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Photosynthetica 2010, Vol.48 (2), p.219-226
Hauptverfasser: Hogewoning, S. W, Trouwborst, G, Harbinson, J, Van Ieperen, W
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The impact of a heterogeneous distribution of actinic light within a leaf chamber for photosynthetic measurements by gas exchange on the photosynthesis-irradiance relationship was investigated. High-resolution light distributions were measured over the area of a commercially available clamp-on leaf chamber equipped with build-in red and blue LEDs, as well as over the area of a custom-made leaf chamber with external light source, using a low-cost digital camera and freely available software. The impact of the measured heterogeneity on the photosynthesis-irradiance response curve was calculated for two realistic scenarios. When the average light intensity over the leaf chamber area was estimated accurately, heterogeneity had minor effects on the photosynthesis-irradiance response curve. However, when the irradiance was measured in the chamber centre, which is common practice, and assumed to be homogeneous, for both leaf chambers the photosynthesis-irradiance response curve was subject to considerable error and led to serious underestimation of the light-limited quantum yield of photosynthesis. Additionally, mixed light sources with different heterogeneity patterns per light source, such as in the clamp-on leaf chamber, potentially increase errors due to heterogeneous physiological responses to light spectrum. High-resolution quantification of the leaf-chamber light distribution enables calculation of the correct average light intensity and already resolves the most pressing problems associated with heterogeneity. To exclude any light-distribution related errors in gas-exchange measurements a leaf chamber and actinic irradiance source design with a homogeneous light distribution is an absolute requirement.
ISSN:0300-3604
1573-9058
DOI:10.1007/s11099-010-0027-2