Some neural and behavioural aspects of electrical and mechanical stunning in ostriches
Different electrical and mechanical stunning procedures were studied in ostriches to determine the effectiveness of the method. Fifty-eight South-African Black ostriches were equipped with EEG electrodes and stunned with three different electrical head-only methods and with a new captive needle pist...
Gespeichert in:
Veröffentlicht in: | Meat science 1999-08, Vol.52 (4), p.339-345 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Different electrical and mechanical stunning procedures were studied in ostriches to determine the effectiveness of the method. Fifty-eight South-African Black ostriches were equipped with EEG electrodes and stunned with three different electrical head-only methods and with a new captive needle pistol, using air pressure. The first stunning procedure consists of two trials. In the first trial a total of 45 ostriches were stunned with a voltage of 200
V (spiked electrodes) during 1
s. Unfortunately, in 10 animals the electrodes were disconnected. A general epileptiform insult on the EEG followed by recovery was observed in 20 ostriches. Another eight animals died after recovery and five showed an iso-electric line and were dead. The total duration of the insult was 25±10
s. The measured current was 463±120
mA. In the second trial a constant current of 400
mA was administered to 13 ostriches. In one animal the electrodes were disconnected. Eight out of 12 animals showed a general epileptiform insult, two of them showed an iso-electric line and two did not show the characteristics of a general epileptiform insult. The total duration of the insult on the EEG was 21±8
s. The measured current was 365±91
mA and the voltage 191±27
V. During the second stunning procedure four and seven ostriches were stunned with 200
V (spiked electrodes) and 48
V (blunt electrodes), respectively, during approx. 6
s. They all died. In addition, a group of 20 ostriches stunned with captive needle pistol using air pressure showed unconsciousness after stunning by the appearance of theta and delta waves tending to an iso-electric line on the EEG trace. It is recommended to use at least 500
mA to stun ostriches effectively and to use a short stun-stick interval or to kill them by a long stunning duration. The captive needle pistol, using air pressure, can be an alternative for electrical head-only stunning. |
---|---|
ISSN: | 0309-1740 1873-4138 |
DOI: | 10.1016/S0309-1740(99)00011-X |