Reproducibility of solidification and melting processes in a latent heat thermal storage tank
This study analyzes the reproducibility of solidification and melting tests in a tank containing 181 kg of paraffin for cold storage at around 8 °C. Firstly, an experimental campaign of 10 identical tests was carried out. The performance is practically the same in terms of PCM temperatures and therm...
Gespeichert in:
Hauptverfasser: | , , , , |
---|---|
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This study analyzes the reproducibility of solidification and melting tests in a tank containing
181 kg of paraffin for cold storage at around 8 °C. Firstly, an experimental campaign
of 10 identical tests was carried out. The performance is practically the same in terms of
PCM temperatures and thermal power, with a maximum deviation of 2% in the capacity of
all tests. In a second campaign, the impact of the initial conditions was studied. The results
indicate that fixing a same mean PCM temperature at the beginning of the tests is insufficient
to ensure an accurate reproducibility. Depending on the heat transfer rate during the
preparation tests, the capacity differed in up to 33%. In tanks with such quantities of PCM,
fixing a uniform initial PCM temperature is hardly possible, thus it is important to prepare
the tank with same operation conditions.
Bosholm, F.; López Navarro, A.; Gamarra, M.; Corberán Salvador, JM.; Payá Herrero, J. (2016). Reproducibility of solidification and melting processes in a latent heat thermal storage tank. International Journal of Refrigeration. 62:85-96. doi:10.1016/j.ijrefrig.2015.10.016 |
---|