Detection of Broken Rotor Bars in Nonlinear Startups of Inverter-Fed Induction Motors

[EN] Fault detection in induction motors powered by inverters operating in nonstationary regimes remains a challenge. The trajectory in the time-frequency plane of harmonics related to broken rotor bar develops very in proximity to the path described by the fundamental component. In addition, their...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Fernández-Cavero, Vanessa, Pons Llinares, Joan, Duque-Perez, Oscar, Morinigo-Sotelo, Daniel
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:[EN] Fault detection in induction motors powered by inverters operating in nonstationary regimes remains a challenge. The trajectory in the time-frequency plane of harmonics related to broken rotor bar develops very in proximity to the path described by the fundamental component. In addition, their energy is much lower than the amplitude of the first harmonic. These two characteristics make it challenging to observe them. The Dragon Transform (DT), here presented, is developed to overcome the described problem. In this article, the DT is assessed with nonlinear inverter-fed startups, where its high time and frequency resolutions facilitate the monitoring of fault harmonics even with highly adjacent trajectories to the first harmonic path. Fernández-Cavero, V.; Pons Llinares, J.; Duque-Perez, O.; Morinigo-Sotelo, D. (2021). Detection of Broken Rotor Bars in Nonlinear Startups of Inverter-Fed Induction Motors. IEEE Transactions on Industry Applications. 57(3):2559-2568. https://doi.org/10.1109/TIA.2021.3066317