Mind the Gap in TAVR: Recognizing and Managing Misloaded Self-Expanding TAVR Devices

Misloading during transcatheter aortic valve replacement (TAVR) is rare but can cause unpredictable valve release if unrecognized. We describe how to identify a misloaded ACURATE neo2 device, and 3 methods to solve this by using a modified technique of valve deployment, ipsilateral extraction, and c...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:JACC. Case reports 2024-02, Vol.29 (3), p.102192
Hauptverfasser: Omar, Aninda, Damlin, Anna, Rück, Andreas, Settergren, Magnus, Verouhis, Dinos, Linder, Rickard, Meduri, Christopher U, Saleh, Nawzad
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Misloading during transcatheter aortic valve replacement (TAVR) is rare but can cause unpredictable valve release if unrecognized. We describe how to identify a misloaded ACURATE neo2 device, and 3 methods to solve this by using a modified technique of valve deployment, ipsilateral extraction, and contralateral valve externalization with extracorporeal valve release.
ISSN:2666-0849
DOI:10.1016/j.jaccas.2023.102192