Differential privacy preserved federated transfer learning for multi-institutional 68 Ga-PET image artefact detection and disentanglement

Image artefacts continue to pose challenges in clinical molecular imaging, resulting in misdiagnoses, additional radiation doses to patients and financial costs. Mismatch and halo artefacts occur frequently in gallium-68 ( Ga)-labelled compounds whole-body PET/CT imaging. Correcting for these artefa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European journal of nuclear medicine and molecular imaging 2023-12, Vol.51 (1), p.40
Hauptverfasser: Shiri, Isaac, Salimi, Yazdan, Maghsudi, Mehdi, Jenabi, Elnaz, Harsini, Sara, Razeghi, Behrooz, Mostafaei, Shayan, Hajianfar, Ghasem, Sanaat, Amirhossein, Jafari, Esmail, Samimi, Rezvan, Khateri, Maziar, Sheikhzadeh, Peyman, Geramifar, Parham, Dadgar, Habibollah, Bitrafan Rajabi, Ahmad, Assadi, Majid, Bénard, François, Vafaei Sadr, Alireza, Voloshynovskiy, Slava, Mainta, Ismini, Uribe, Carlos, Rahmim, Arman, Zaidi, Habib
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Image artefacts continue to pose challenges in clinical molecular imaging, resulting in misdiagnoses, additional radiation doses to patients and financial costs. Mismatch and halo artefacts occur frequently in gallium-68 ( Ga)-labelled compounds whole-body PET/CT imaging. Correcting for these artefacts is not straightforward and requires algorithmic developments, given that conventional techniques have failed to address them adequately. In the current study, we employed differential privacy-preserving federated transfer learning (FTL) to manage clinical data sharing and tackle privacy issues for building centre-specific models that detect and correct artefacts present in PET images. Altogether, 1413 patients with Ga prostate-specific membrane antigen (PSMA)/DOTA-TATE (TOC) PET/CT scans from 3 countries, including 8 different centres, were enrolled in this study. CT-based attenuation and scatter correction (CT-ASC) was used in all centres for quantitative PET reconstruction. Prior to model training, an experienced nuclear medicine physician reviewed all images to ensure the use of high-quality, artefact-free PET images (421 patients' images). A deep neural network (modified U2Net) was trained on 80% of the artefact-free PET images to utilize centre-based (CeBa), centralized (CeZe) and the proposed differential privacy FTL frameworks. Quantitative analysis was performed in 20% of the clean data (with no artefacts) in each centre. A panel of two nuclear medicine physicians conducted qualitative assessment of image quality, diagnostic confidence and image artefacts in 128 patients with artefacts (256 images for CT-ASC and FTL-ASC). The three approaches investigated in this study for Ga-PET imaging (CeBa, CeZe and FTL) resulted in a mean absolute error (MAE) of 0.42 ± 0.21 (CI 95%: 0.38 to 0.47), 0.32 ± 0.23 (CI 95%: 0.27 to 0.37) and 0.28 ± 0.15 (CI 95%: 0.25 to 0.31), respectively. Statistical analysis using the Wilcoxon test revealed significant differences between the three approaches, with FTL outperforming CeBa and CeZe (p-value 
ISSN:1619-7070
1619-7089
DOI:10.1007/s00259-023-06418-7