A Prospective Randomized Trial on the Effect of Using an Electronic Monitoring Drug Dispensing Device to Improve Adherence and Compliance

BACKGROUNDOutcome after renal transplantation depends on patient compliance and adherence for early detection of complications and identification of intervention opportunities. Compliance describes the degree to which patients follow medical advice and take their medications. Adherence has been defi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Transplantation 2016-01, Vol.100 (1), p.203-209
Hauptverfasser: Henriksson, Jarmo, Tydén, Gunnar, Höijer, Jonas, Wadström, Jonas
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:BACKGROUNDOutcome after renal transplantation depends on patient compliance and adherence for early detection of complications and identification of intervention opportunities. Compliance describes the degree to which patients follow medical advice and take their medications. Adherence has been defined as the extent to which a patientsʼ behavior coincides with clinical prescriptions. MATERIALS AND METHODSPatients were randomized 7 to 14 days after transplantation into groups with (n = 40) and without (n = 40) an electronic medication dispenser (EMD). The EMD, which was used for the 1-year study period, recorded the date and time the patient took their medications and was monitored via a web-based application. Patients were monitored for 1 year regarding outpatient follow-up visits, emergency hospitalizations, renal biopsies, rejection episodes, renal function, and blood concentration of medications. RESULTSCompliance in the intervention group was 97.8% (the control group was not assessed). Number of missed doses varied significantly by weekday (P = 0.033); patients were most likely to miss doses on Saturdays and Thursdays. Patients missed a total of 11 follow-up visits. During the study, 92 biopsies were performed on 55 patients (intervention group32 [17]; control group, 60 [38]). Biopsy-verified rejection was three times more common among controls (13 patients vs 4; P = 0.054, not significant). Average P-creatinine level was slightly lower in the intervention group than the control group (131 vs 150 μmol/L, not significant), whereas mean tacrolimus was similar (7.32 vs 7.22 ng/mL, n.s.). CONCLUSIONSThe EMD is associated with high compliance, and there are also indications of a lower rejection rate.
ISSN:0041-1337
1534-6080
DOI:10.1097/TP.0000000000000971