Agreement of the Resting Distal to Aortic Coronary Pressure With the Instantaneous Wave-Free Ratio

Recently, 2 randomized controlled trials showed that the instantaneous wave-free ratio (iFR), a resting coronary physiological index, is noninferior to fractional flow reserve for guiding revascularization. The resting distal to aortic coronary pressure (Pd/Pa) measured at rest is another adenosine-...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the American College of Cardiology 2017-10, Vol.70 (17), p.2105-2113
Hauptverfasser: Kobayashi, Yuhei, Johnson, Nils P., Zimmermann, Frederik M., Witt, Nils, Berry, Colin, Jeremias, Allen, Koo, Bon-Kwon, Esposito, Giovanni, Rioufol, Gilles, Park, Seung-Jung, Nishi, Takeshi, Choi, Dong-Hyun, Oldroyd, Keith G., Barbato, Emanuele, Pijls, Nico H.J., De Bruyne, Bernard, Fearon, William F.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Recently, 2 randomized controlled trials showed that the instantaneous wave-free ratio (iFR), a resting coronary physiological index, is noninferior to fractional flow reserve for guiding revascularization. The resting distal to aortic coronary pressure (Pd/Pa) measured at rest is another adenosine-free index widely available in the cardiac catheterization laboratory; however, little is known about the agreement of Pd/Pa using iFR as a reference standard. The goal of this study was to investigate the agreement of Pd/Pa with iFR. A total of 763 patients were prospectively enrolled from 12 institutions. iFR and Pd/Pa were measured under resting conditions. Using iFR ≤0.89 as a reference standard, the agreement of Pd/Pa and its best cutoff value were assessed. According to the independent core laboratory analysis, iFR and Pd/Pa were analyzable in 627 and 733 patients (82.2% vs. 96.1%; p < 0.001), respectively. The median iFR and Pd/Pa were 0.90 (interquartile range: 0.85 to 0.94) and 0.92 (interquartile range: 0.88 to 0.95), and the 2 indices were highly correlated (R2 = 0.93; p < 0.001; iFR = 1.31 * Pd/Pa –0.31). According to the receiver-operating characteristic curve analysis, Pd/Pa showed excellent agreement (area under the curve: 0.98; 95% confidence interval: 0.97 to 0.99; p < 0.001) with a best cutoff value of Pd/Pa ≤0.91. The diagnostic accuracy, sensitivity, specificity, positive predictive value, and negative predictive value were 93.0%, 91.4%, 94.4%, 93.3%, and 92.7%, respectively. These results were similar in patients with acute coronary syndrome and stable angina. Pd/Pa was analyzable in a significantly higher number of patients than iFR. Pd/Pa showed excellent agreement with iFR, suggesting that it could be applied clinically in a similar fashion. (Can Contrast Injection Better Approximate FFR Compared to Pure Resting Physiology? [CONTRAST]; NCT02184117) [Display omitted]
ISSN:0735-1097
1558-3597
DOI:10.1016/j.jacc.2017.08.049