Performance of pulse palpation compared to one‐lead ECG in atrial fibrillation screening
Background The 2020 European Society of Cardiology atrial fibrillation guidelines recommend opportunistic screening for atrial fibrillation by pulse taking or ECG rhythm strip in those aged over 65 years. Hypothesis We aimed to compare the diagnostic accuracy of pulse palpation to ECG rhythm strip w...
Gespeichert in:
Veröffentlicht in: | Clinical cardiology (Mahwah, N.J.) N.J.), 2021-05, Vol.44 (5), p.692-698 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background
The 2020 European Society of Cardiology atrial fibrillation guidelines recommend opportunistic screening for atrial fibrillation by pulse taking or ECG rhythm strip in those aged over 65 years.
Hypothesis
We aimed to compare the diagnostic accuracy of pulse palpation to ECG rhythm strip when screening for atrial fibrillation. A secondary aim was to investigate whether participants with palpitations were more likely to be diagnosed with new atrial fibrillation.
Methods
The study population were 75/76 year old individuals that participated in the STROKESTOP II study, a Swedish screening study for atrial fibrillation. Pulse palpation of the radial pulse for 30 sec was performed by healthcare professionals and recorded as regular or irregular. Thereafter a 30‐sec single‐lead ECG was registered. Patients were asked also if they had a history of palpitations.
Results
Of the 6159 participants included in the study, 461 (7.5%) had irregular pulse. Twenty‐two (4.8%) of those with irregular pulse were diagnosed with atrial fibrillation on single‐lead ECG rhythm strip. Among those with regular pulse, 6 (0.1%) cases of new atrial fibrillation were found. The sensitivity of the pulse palpation test was 78.6% and positive predictive value 4.8%. The proportion of newly diagnosed atrial fibrillation was not different between those with and without history of palpitations.
Conclusion
Pulse palpation was inferior to single‐lead ECG when screening for atrial fibrillation. We therefore advocate the use of single‐lead ECG rather than pulse palpation when screening for atrial fibrillation. Palpitations did not predict atrial fibrillation. |
---|---|