Adverse events and their management during enhanced external counterpulsation treatment in patients with refractory angina pectoris: observations from a routine clinical practice

Enhanced external counterpulsation (EECP) is a non-invasive treatment (35 one-hour sessions) for patients with refractory angina pectoris (RAP). To avoid interruption of treatment, more knowledge is needed about potential adverse events (AE) of EECP and their appropriate management. To describe occu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European journal of cardiovascular nursing : journal of the Working Group on Cardiovascular Nursing of the European Society of Cardiology 2022-03, Vol.21 (2), p.152-160
Hauptverfasser: Wu, Eline, Mårtensson, Jan, Desta, Liyew, Broström, Anders
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Enhanced external counterpulsation (EECP) is a non-invasive treatment (35 one-hour sessions) for patients with refractory angina pectoris (RAP). To avoid interruption of treatment, more knowledge is needed about potential adverse events (AE) of EECP and their appropriate management. To describe occurrence of AE and clinical actions related to EECP treatment in patients with RAP and compare the distribution of AE between responders and non-responders to treatment. A retrospective study was conducted by reviewing medical records of 119 patients with RAP who had undergone one EECP treatment and a 6-min-walk test pre- and post-treatment. Sociodemographic, medical, and clinical data related to EECP were collected from patients' medical records. An increased walking distance by 10% post-treatment, measured by 6-min-walk test, was considered a responder. The treatment completion rate was high, and the occurrence of AE was low. Adverse events occurred more often in the beginning and gradually decreased towards the end of EECP treatment. The AE were either device related (e.g. muscle pain/soreness) or non-device related (e.g. bradycardia). Medical (e.g. medication adjustments) and/or nursing (e.g. extra padding around the calves, wound dressing) actions were used. The AE distribution did not differ between responders (n = 49, 41.2%) and non-responders. Skin lesion/blister occurred mostly in responders and paraesthesia occurred mostly in non-responders. Enhanced external counterpulsation appears to be a safe and well-tolerated treatment option in patients with RAP. However, nurses should be attentive and flexible to meet their patients' needs to prevent AE and early termination of treatment.
ISSN:1474-5151
1873-1953
1873-1953
DOI:10.1093/eurjcn/zvab040