Comparison of microgyro-based measurements of equine metatarsal/metacarpal bone to a high speed video locomotion analysis system during treadmill locomotion

The aim of this study was to compare an inertial motion system (IMS) to an optical based locomotion analysis system measuring limb sagittal segment angles in horses at the walk and trot. The metatarsal/metacarpal bones of two horses (20 trials) were fitted with optical system markers and an IMS. Bet...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The veterinary journal (1997) 2013-12, Vol.198, p.e157-e160
Hauptverfasser: Roepstorff, L., Wiestner, T., Weishaupt, M.A., Egenvall, E.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The aim of this study was to compare an inertial motion system (IMS) to an optical based locomotion analysis system measuring limb sagittal segment angles in horses at the walk and trot. The metatarsal/metacarpal bones of two horses (20 trials) were fitted with optical system markers and an IMS. Between the systems, measuring range of motion (ROM) of the sagittal metatarsal/metacarpal bone angles, the IMS measured higher ROM than the optical system (bias 1.6°; precision at 1.96 standard deviation 1.9°). The same angle data were used to assess inter-limb symmetry by calculating phase shift between the limbs within a stride. This showed essentially no bias and the precision was 0.025%. The IMS has potential for quantification of ROM and phase shift of equine distal limb movement.
ISSN:1090-0233
1532-2971
1532-2971
DOI:10.1016/j.tvjl.2013.09.052