Homogeneity density scores of quarter milk in automatic milking systems

Milk quality and clinical mastitis in dairy cows are monitored by detecting visually abnormal milk. A standardized method to evaluate clots in milk and studies of the incidence and dynamics of clots in milk at the quarter level are lacking. We validated a method to score clot density in quarter milk...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of dairy science 2021-09, Vol.104 (9), p.10121-10130
Hauptverfasser: Hallén Sandgren, C., Anglart, D., Klaas, I.C., Rönnegård, L., Emanuelson, U.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Milk quality and clinical mastitis in dairy cows are monitored by detecting visually abnormal milk. A standardized method to evaluate clots in milk and studies of the incidence and dynamics of clots in milk at the quarter level are lacking. We validated a method to score clot density in quarter milk samples and describe the prevalence and dynamics of the density scores between consecutive samplings and periods in 4 farms with automatic milking systems. Using in-line filters, we collected quarter milk samples at each milking during 3 periods of 30 h each in each farm. Clot density was scored based on coverage of the filter area as 0 (negative), 1 (trace), 2 (mild), 3 (moderate), 4 (heavy), and 5 (very heavy). The score for a specific quarter and milking is referred to as the quarter milking score (QMS). Three assessors independently scored 902 images of filter samples with a Fleiss kappa value of 0.72. In total, 21,202 quarter milk samples from 5,398 milkings of 621 cows were collected. Of the quarter filter samples, 2.4% had visible clots, distributed as mild (1.4%), moderate (0.6%), heavy (0.3%), and very heavy (1 in the following milking, with an average chance of 38%. The probability of a QMS > 1 increased with increasing previous QMS, a higher sum of QMS during the milking period, longer milking interval, and higher lactation number, but decreased with increasing days in milk. Our study showed that the method of clot-density scoring is feasible to perform and reproducible for investigating the occurrence and dynamics of clots in milk. Elevated clot-density scores clustered within certain cows and cow periods and appeared in new quarters of the cows over time. The low recurrence of QMS of 1 and 2 within quarters indicated that QMS 3 could be a reasonable threshold for detecting quarters with abnormal milk that require further attention.
ISSN:0022-0302
1525-3198
1525-3198
DOI:10.3168/jds.2021-20439