End-expiratory lung volume remains stable during N 2 MBW in healthy sleeping infants

We have previously shown that functional residual capacity (FRC) and lung clearance index were significantly greater in sleeping healthy infants when measured by N (nitrogen) washout using 100% O (oxygen) versus 4% SF (sulfur hexafluoride) washout using air. Following 100% O exposure, tidal volumes...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physiological reports 2020-08, Vol.8 (16), p.e14477
Hauptverfasser: Gustafsson, Per M, Kadar, Laszlo, Kjellberg, Sanna, Andersson, Lena, Lindblad, Anders, Robinson, Paul D
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We have previously shown that functional residual capacity (FRC) and lung clearance index were significantly greater in sleeping healthy infants when measured by N (nitrogen) washout using 100% O (oxygen) versus 4% SF (sulfur hexafluoride) washout using air. Following 100% O exposure, tidal volumes decreased by over 30%, while end-expiratory lung volume (EELV, i.e., FRC) rose markedly based on ultrasonic flow meter assessments. In the present study to investigate the mechanism behind the observed changes, N MBW was performed in 10 separate healthy full-term spontaneously sleeping infants, mean (range) 26 (18-31) weeks, with simultaneous EELV monitoring (respiratory inductance plethysmography, RIP) and oxygen uptake (V´O ) assessment during prephase air breathing, during N washout by exposure to 100% O , and subsequently during air breathing. While flow meter signals suggested a rise in ELLV by mean (SD) 26 (9) ml over the washout period, RIP signals demonstrated no EELV change. V'O /FRC ratio during air breathing was mean (SD) 0.43 (0.08)/min, approximately seven times higher than that calculated from adult data. We propose that our previously reported flow meter-based overestimation of EELV was in fact a physiological artifact caused by rapid and marked movement of O across the alveolar capillary membrane into the blood and tissue during 100% O exposure, without concomitant transfer of N to the same degree in the opposite direction. This may be driven by the high observed O consumption and resulting cardiac output encountered in infancy. Furthermore, the low resting lung volume in infancy may make this error in lung volume determination by N washout relatively large.
ISSN:2051-817X
2051-817X
DOI:10.14814/phy2.14477