A city-level assessment of residential PV hosting capacity for low-voltage distribution systems considering rooftop data and uncertainties
The increasing trend of small-scale residential photovoltaic (PV) system installation in low-voltage (LV) distribution networks poses challenges for power grids. To quantify these impacts, hosting capacity has become a popular framework for analysis. However, previous studies have mostly focused on...
Gespeichert in:
Veröffentlicht in: | Applied energy 2024-10, Vol.371, p.123715, Article 123715 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The increasing trend of small-scale residential photovoltaic (PV) system installation in low-voltage (LV) distribution networks poses challenges for power grids. To quantify these impacts, hosting capacity has become a popular framework for analysis. However, previous studies have mostly focused on small-scale or test feeders and overlooked uncertainties related to rooftop azimuth and tilt. This paper presents a comprehensive evaluation of city-level PV hosting capacity using data from over 300 real LV systems in Varberg, Sweden. A previously developed rooftop azimuth and tilt model is also applied and evaluated. The findings indicate that the distribution systems of the city, with a definition of PV penetration as the percentage of houses with 12 kW installed PV systems, can accommodate up to 90% PV penetration with less than 1% risk of overvoltage, and line loading is not a limiting factor. The roof facet orientation modeling proves to be suitable for city-level applications due to its simplicity and effectiveness. Sensitivity studies reveal that PV system size assumptions significantly influence hosting capacity analysis. The study provides valuable insights for planning strategies to increase PV penetration in residential buildings and offers technical input for regulators and grid operators to facilitate and manage residential PV systems.
•PV hosting capacity analysis for over 300 real LV systems, in Varberg, Sweden.•LiDAR-based rooftops model for around 37,000 buildings and historical load profiles for around 11,800 end-customers were utilized.•The studied city can accommodate up to 90% PV penetration with less than 1% risk of overvoltage, and line loading is not a limiting factor.•Roof facet orientation and PV system size assumptions significantly influence hosting capacity analysis.•The previously developed roof facet orientation model was proved to be suitable for city-level applications. |
---|---|
ISSN: | 0306-2619 1872-9118 |
DOI: | 10.1016/j.apenergy.2024.123715 |