Performance of a capnodynamic method estimating cardiac output during respiratory failure - before and after lung recruitment

Respiratory failure may cause hemodynamic instability with strain on the right ventricle. The capnodynamic method continuously calculates cardiac output (CO) based on effective pulmonary blood flow (CO EPBF ) and could provide CO monitoring complementary to mechanical ventilation during surgery and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of clinical monitoring and computing 2020-12, Vol.34 (6), p.1199-1207
Hauptverfasser: Sigmundsson, Thorir Svavar, Öhman, Tomas, Hallbäck, Magnus, Redondo, Eider, Sipmann, Fernando Suarez, Wallin, Mats, Oldner, Anders, Hällsjö-Sander, Caroline, Björne, Håkan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Respiratory failure may cause hemodynamic instability with strain on the right ventricle. The capnodynamic method continuously calculates cardiac output (CO) based on effective pulmonary blood flow (CO EPBF ) and could provide CO monitoring complementary to mechanical ventilation during surgery and intensive care. The aim of the current study was to evaluate the ability of a revised capnodynamic method, based on short expiratory holds (CO EPBFexp ), to estimate CO during acute respiratory failure (LI) with high shunt fractions before and after compliance-based lung recruitment. Ten pigs were submitted to lung lavage and subsequent ventilator-induced lung injury. CO EPBFexp , without any shunt correction, was compared to a reference method for CO, an ultrasonic flow probe placed around the pulmonary artery trunk (CO TS ) at (1) baseline in healthy lungs with PEEP 5 cmH 2 O (HL P5 ), (2) LI with PEEP 5 cmH 2 O (LI P5 ) and (3) LI after lung recruitment and PEEP adjustment (LI Padj ). CO changes were enforced during LI P5 and LI Padj to estimate trending. LI resulted in changes in shunt fraction from 0.1 (0.03) to 0.36 (0.1) and restored to 0.09 (0.04) after recruitment manoeuvre. Bias (levels of agreement) and percentage error between CO EPBFexp and CO TS changed from 0.5 (− 0.5 to 1.5) L/min and 30% at HL P5 to − 0.6 (− 2.3 to 1.1) L/min and 39% during LI P5 and finally 1.1 (− 0.3 to 2.5) L/min and 38% at LI Padj . Concordance during CO changes improved from 87 to 100% after lung recruitment and PEEP adjustment. CO EPBFexp could possibly be used for continuous CO monitoring and trending in hemodynamically unstable patients with increased shunt and after recruitment manoeuvre.
ISSN:1387-1307
1573-2614
1573-2614
DOI:10.1007/s10877-019-00421-w