This work presents a procedure based on spatially-resolved near-infrared imaging, in order to observe temperature and composition maps in gas–solid packed beds subjected to effects of aspect ratio and non-isothermal conditions. The technique was applied to the water vapour flow in a packed bed adsor...
Gespeichert in:
Veröffentlicht in: | Chemical engineering science 2011, Vol.66 (24), p.6407-6423 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This work presents a procedure based on spatially-resolved near-infrared imaging, in order to observe temperature and composition maps in gas–solid packed beds subjected to effects of aspect ratio and non-isothermal conditions. The technique was applied to the water vapour flow in a packed bed adsorber of low aspect ratio, filled with silica gel, using a tuneable diode laser, focal planar array detector and tomographic reconstruction. The 2D projected images from parallel scanning permitted data to be retrieved from the packing and above the packing sections of 12.0×12.0×18.2
mm
3 at a volume-resolution of 0.15×0.15×0.026
mm
3 and a time-resolution of less than 3
min. The technique revealed uneven temperature and composition maps in the core packed bed and in the vicinity of the wall due to flow maldistribution. In addition, the heat uptake from the packed bed and local cross-mixing were experimentally ascertained by local profiles of the water vapour composition and temperature under various aspect ratios and feed flow rates. The relative deviations in temperature and compositions were 11.1% and 9.3%, respectively. The deviation in composition, which covers the packing and above the packing sections, was slightly higher than the deviation of 8% obtained up-to-date but was limited to the exit of a packed bed adsorber.
► 3D distribution of temperature and water vapour composition by NIR tomography. ► The technique relied on a tunable laser, focal planar array detector and tomographic reconstruction. ► Flow maldistribution was observed in a packed bed adsorber of low aspect ratio. ► Heat uptake from the packed bed and local cross-mixing were experimentally ascertained. |
---|---|