Application of 1/ f current noise for quality and age monitoring of electrochromic devices
This is a continuation of an earlier study on 1/ f noise in electrochromic (EC) devices undergoing discharge via a resistor. The EC devices comprised films of W oxide and Ni–V oxide joined by a polymer electrolyte, and with this three-layer stack positioned between transparent conducting In 2O 3:Sn...
Gespeichert in:
Veröffentlicht in: | Solar energy materials and solar cells 2008-08, Vol.92 (8), p.914-918 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This is a continuation of an earlier study on 1/
f noise in electrochromic (EC) devices undergoing discharge via a resistor. The EC devices comprised films of W oxide and Ni–V oxide joined by a polymer electrolyte, and with this three-layer stack positioned between transparent conducting In
2O
3:Sn films backed by polyester foils. We also investigated “symmetrical” devices with two identical films of W oxide or Ni–V oxide. The power spectral density
S
i
at fixed frequency scaled with current (
I) as
S
i
∼
I
2. Color/bleach cycling for about 2500 times degraded the optical properties and homogeneity of the EC devices and increased the 1/
f noise intensity by a factor of four, which confirms the earlier assumption that 1/
f noise has a good potential to serve as quality and aging assessment for EC devices. Studies of “symmetrical” devices proved that the noise was mainly associated with the Ni oxide, and measurements on individual parts of an EC device indicated that the 1/
f noise originated from localized areas. |
---|---|
ISSN: | 0927-0248 1879-3398 1879-3398 |
DOI: | 10.1016/j.solmat.2008.02.035 |