Examination of the reliability of x-ray techniques for determining hydrogen-induced volume changes
The Bragg peaks in x-ray diffraction experiments are generally taken to be a reliable measure of the average lattice distance in crystals. We show that this assumption can be misleading when determining hydrogen-induced volume changes. Experiments based on simultaneous determination of the position...
Gespeichert in:
Veröffentlicht in: | Physical review. B, Condensed matter and materials physics Condensed matter and materials physics, 2008-09, Vol.78 (10), p.104118, Article 104118 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The Bragg peaks in x-ray diffraction experiments are generally taken to be a reliable measure of the average lattice distance in crystals. We show that this assumption can be misleading when determining hydrogen-induced volume changes. Experiments based on simultaneous determination of the position of the Bragg peak and the sample volume of an Fe/V(001) superlattice while expanding the lattice by in situ hydrogen loading serve as an illustration of this counter-intuitive effect. |
---|---|
ISSN: | 1098-0121 1550-235X 1550-235X |
DOI: | 10.1103/PhysRevB.78.104118 |