The clinical value of total isovolumic time

The objective of this thesis is to evaluate the use of Doppler echocardiography markers ofglobal dyssynchrony [total isovolumic time (t-IVT)] in the following 6 studies: 1) Its prognostic role in predicting cardiac events in patients undergoing CABG surgery,compared with conventional global systolic...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
1. Verfasser: Bajraktari, Gani
Format: Dissertation
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The objective of this thesis is to evaluate the use of Doppler echocardiography markers ofglobal dyssynchrony [total isovolumic time (t-IVT)] in the following 6 studies: 1) Its prognostic role in predicting cardiac events in patients undergoing CABG surgery,compared with conventional global systolic and diastolic measurements. 2) Its additional value in predicting six minute walk test (6-MWT) in patients with leftventricular (LV) ejection fraction (EF) <45%. 3) Its prognostic value in comparison with other clinical, biochemical and echocardiographicvariables in patients with chronic systolic heart failure (HF). 4) The relationship between 6-MWT and cardiac function measurements in a consecutivegroup of patients, irrespective of EF and to identify predictors of exercise capacity. 5) To investigate the effect of age on LV t-IVT and Tei index compared with conventionalsystolic and diastolic parameters. 6) To assess potential additional value of markers of global LV dyssynchrony in predictingcardiac resynchronization therapy (CRT) response in HF patients. Study I Methods: This study included 74 patients before routine CABG who were followed up for18±12 months. Results: At follow-up, 29 patients were hospitalized for a cardiac event or died. LV-ESD wasgreater (P=0.003), fractional shortening (FS) lower (p<0.001), E:A ratio and Tei index higher(all P<0.001), and t-IVT longer (P<0.001) in patients with events. Low FS [0.66 (0.50–0.87),P<0.001], high E:A ratio [l4.13 (1.17–14.60), P=0.028], large LV-ESD [0.19 (0.05–0.84),P=0.029], and long t-IVT [1.37 (1.02–1.84), P=0.035] predicted events and deaths. Conclusion: Despite satisfactory surgical revascularization, long t-IVT and systolicdysfunction suggest persistent ventricular dyssynchrony that contributes to post-CABGcardiac events. Study II Methods: We studied 77 patients (60±12 year, and 33.3% females) with stable HF using 6-MWT.iii Results: E’ wave (r=0.61, p<0.001), E/e’ ratio (r=-0.49, p<0.001), t-IVT (r=-0.44, p<0.001),Tei index (r=-0.43, p<0.001) and NYHA class (r=-0.53, p<0.001) had the highest correlationwith the 6-MWT distance. In multivariate analysis, only E/e’ ratio [0.800 (0.665-0.961),p=0.017], and t-IVT [0.769 (0.619-0.955), p=0.018] independently predicted poor 6-MWTperformance (<300m). Conclusions: In HF, the higher the filling pressures and the more dyssynchronous the LV, thepoorer is the patient’s exercise capacity. Study III Methods: We studied 107 systolic HF