Radiobiological Evaluation of Breast Cancer Radiotherapy Accounting for the Effects of Patient Positioning and Breathing in Dose Delivery. A Meta Analysis

In breast cancer radiotherapy, significant discrepancies in dose delivery can contribute to underdosage of the tumor or overdosage of normal tissue, which is potentially related to a reduction of local tumor control and an increase of side effects. To study the impact of these factors in breast canc...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Technology in cancer research & treatment 2013-02, Vol.12 (1), p.31-44
Hauptverfasser: Tzikas, Athanasios, Komisopoulos, Georgios, Ferreira, Brigida Costa, Hyödynmaa, Simo, Axelsson, Sofie, Papanikolaou, Nikos, Lavdas, Eleftherios, Lind, Bengt K., Mavroidis, Panayiotis
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In breast cancer radiotherapy, significant discrepancies in dose delivery can contribute to underdosage of the tumor or overdosage of normal tissue, which is potentially related to a reduction of local tumor control and an increase of side effects. To study the impact of these factors in breast cancer radiotherapy, a meta analysis of the clinical data reported by Mavroidis et al. (2002) in Acta Oncol (41:471–85), showing the patient setup and breathing uncertainties characterizing three different irradiation techniques, were employed. The uncertainties in dose delivery are simulated based on fifteen breast cancer patients (5 mastectomized, 5 resected with negative node involvement (R-) and 5 resected with positive node involvement (R+)), who were treated by three different irradiation techniques, respectively. The positioning and breathing effects were taken into consideration in the determination of the real dose distributions delivered to the CTV and lung in each patient. The combined frequency distributions of the positioning and breathing distributions were obtained by convolution. For each patient the effectiveness of the dose distribution applied is calculated by the Poisson and relative seriality models and a set of parameters that describe the dose-response relations of the target and lung. The three representative radiation techniques are compared based on radiobiological measures by using the complication-free tumor control probability, P+ and the biologically effective uniform dose, D̿ concepts. For the Mastectomy case, the average P+ values of the planned and delivered dose distributions are 93.8% for a D̿CTV of 51.8 Gy and 85.0% for a D̿CTV of 50.3 Gy, respectively. The respective total control probabilities, PB values are 94.8% and 92.5%, whereas the corresponding total complication probabilities, PI values are 0.9% and 7.4%. For the R- case, the average P+ values are 89.4% for a D̿CTV of 48.9 Gy and 88.6% for a D̿CTV of 49.0 Gy, respectively. The respective PB values are 89.8% and 89.9%, whereas the corresponding PI values are 0.4% and 1.2%. For the R+ case, the average P+ values are 86.1% for a D̿CTV of 49.2 Gy and 85.5% for a D̿CTV of 49.1 Gy, respectively. The respective PB values are 90.2% and 90.1%, whereas the corresponding PI values are 4.1% and 4.6%. The combined effects of positioning uncertainties and breathing can introduce a significant deviation between the planned and delivered dose distributions in lung in breast cancer radiot
ISSN:1533-0346
1533-0338
1533-0338
DOI:10.7785/tcrt.2012.500274